Merge branch 'fix/wrong_channel_gpio_num_on_p4_adc2' into 'master'
ADC: add continuous parse data API See merge request espressif/esp-idf!40243
This commit is contained in:
@@ -313,6 +313,71 @@ where:
|
||||
|
||||
To do further calibration to convert the ADC raw result to voltage in mV, please refer to :doc:`adc_calibration`.
|
||||
|
||||
Parse ADC Raw Data
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The raw data read from ADC continuous mode needs to be further parsed to obtain usable ADC conversion results. The function :cpp:func:`adc_continuous_parse_data` provides the functionality to parse raw data into structured ADC data.
|
||||
|
||||
.. note::
|
||||
|
||||
Input buffer requirements:
|
||||
|
||||
- **Length alignment**: `raw_data_size` must be a multiple of :c:macro:`SOC_ADC_DIGI_RESULT_BYTES`
|
||||
- **Buffer size**: Ensure the `raw_data` buffer is large enough to hold `raw_data_size` bytes of data
|
||||
|
||||
.. code:: c
|
||||
|
||||
// Read raw data
|
||||
uint32_t ret_num = 0;
|
||||
esp_err_t ret = adc_continuous_read(handle, result, EXAMPLE_READ_LEN, &ret_num, 0);
|
||||
if (ret == ESP_OK) {
|
||||
// Parse raw data
|
||||
adc_continuous_data_t parsed_data[ret_num / SOC_ADC_DIGI_RESULT_BYTES];
|
||||
uint32_t num_parsed_samples = 0;
|
||||
|
||||
esp_err_t parse_ret = adc_continuous_parse_data(handle, result, ret_num, parsed_data, &num_parsed_samples);
|
||||
if (parse_ret == ESP_OK) {
|
||||
for (int i = 0; i < num_parsed_samples; i++) {
|
||||
if (parsed_data[i].valid) {
|
||||
ESP_LOGI(TAG, "ADC%d, Channel: %d, Value: %"PRIu32,
|
||||
parsed_data[i].unit + 1,
|
||||
parsed_data[i].channel,
|
||||
parsed_data[i].raw_data);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
The parsed data structure :cpp:type:`adc_continuous_data_t` contains the following information:
|
||||
|
||||
- :cpp:member:`adc_continuous_data_t::unit`:ADC unit (ADC_UNIT_1 or ADC_UNIT_2)
|
||||
- :cpp:member:`adc_continuous_data_t::channel`:ADC channel number (0-9)
|
||||
- :cpp:member:`adc_continuous_data_t::raw_data`:ADC raw data value (0-4095, 12-bit resolution)
|
||||
- :cpp:member:`adc_continuous_data_t::valid`:Whether the data is valid
|
||||
|
||||
Read and Parse ADC Data
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
To simplify the usage flow, the function :cpp:func:`adc_continuous_read_parse` is provided, which merges the read and parse operations into a single function call.
|
||||
|
||||
.. code:: c
|
||||
|
||||
// Using the read and parse function
|
||||
adc_continuous_data_t parsed_data[64]; // User specifies maximum number of samples
|
||||
uint32_t num_samples = 0;
|
||||
|
||||
esp_err_t ret = adc_continuous_read_parse(handle, parsed_data, 64, &num_samples, 1000);
|
||||
if (ret == ESP_OK) {
|
||||
for (int i = 0; i < num_samples; i++) {
|
||||
if (parsed_data[i].valid) {
|
||||
ESP_LOGI(TAG, "ADC%d, Channel: %d, Value: %"PRIu32,
|
||||
parsed_data[i].unit + 1,
|
||||
parsed_data[i].channel,
|
||||
parsed_data[i].raw_data);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
.. _adc-continuous-hardware-limitations:
|
||||
|
||||
.. _hardware_limitations_adc_continuous:
|
||||
|