mirror of
https://github.com/espressif/esp-idf.git
synced 2025-08-07 20:00:53 +00:00
feat(ble): support for putting ble code into flash on ESP32-C5
This commit is contained in:
@@ -310,6 +310,24 @@ config BT_LE_CONTROLLER_LOG_DUMP_ONLY
|
||||
help
|
||||
Only operate in dump mode
|
||||
|
||||
config BT_LE_CONTROLLER_LOG_STORAGE_ENABLE
|
||||
bool "Store ble controller logs to flash(Experimental)"
|
||||
depends on !BT_LE_CONTROLLER_LOG_DUMP_ONLY
|
||||
depends on BT_LE_CONTROLLER_LOG_ENABLED
|
||||
default n
|
||||
help
|
||||
Store ble controller logs to flash memory.
|
||||
|
||||
config BT_LE_CONTROLLER_LOG_PARTITION_SIZE
|
||||
int "size of ble controller log partition(Multiples of 4K)"
|
||||
depends on BT_LE_CONTROLLER_LOG_STORAGE_ENABLE
|
||||
default 65536
|
||||
help
|
||||
The size of ble controller log partition shall be a multiples of 4K.
|
||||
The name of log partition shall be "bt_ctrl_log".
|
||||
The partition type shall be ESP_PARTITION_TYPE_DATA.
|
||||
The partition sub_type shall be ESP_PARTITION_SUBTYPE_ANY.
|
||||
|
||||
config BT_LE_LOG_CTRL_BUF1_SIZE
|
||||
int "size of the first BLE controller LOG buffer"
|
||||
depends on BT_LE_CONTROLLER_LOG_ENABLED
|
||||
@@ -575,3 +593,83 @@ config BT_LE_SCAN_DUPL_CACHE_REFRESH_PERIOD
|
||||
config BT_LE_MSYS_INIT_IN_CONTROLLER
|
||||
bool "Msys Mbuf Init in Controller"
|
||||
default y
|
||||
|
||||
config BT_LE_TX_CCA_ENABLED
|
||||
bool "Enable TX CCA feature"
|
||||
default n
|
||||
help
|
||||
Enable CCA feature to cancel sending the packet if the signal power is stronger than CCA threshold.
|
||||
|
||||
config BT_LE_CCA_RSSI_THRESH
|
||||
int "CCA RSSI threshold value"
|
||||
depends on BT_LE_TX_CCA_ENABLED
|
||||
range 20 100
|
||||
default 20
|
||||
help
|
||||
Power threshold of CCA in unit of -1 dBm.
|
||||
|
||||
choice BT_LE_DFT_TX_POWER_LEVEL_DBM
|
||||
prompt "BLE default Tx power level(dBm)"
|
||||
default BT_LE_DFT_TX_POWER_LEVEL_P9
|
||||
help
|
||||
Specify default Tx power level(dBm).
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_N15
|
||||
bool "-15dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_N12
|
||||
bool "-12dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_N9
|
||||
bool "-9dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_N6
|
||||
bool "-6dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_N3
|
||||
bool "-3dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_N0
|
||||
bool "0dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_P3
|
||||
bool "+3dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_P6
|
||||
bool "+6dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_P9
|
||||
bool "+9dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_P12
|
||||
bool "+12dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_P15
|
||||
bool "+15dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_P18
|
||||
bool "+18dBm"
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_P20
|
||||
bool "+20dBm"
|
||||
endchoice
|
||||
|
||||
config BT_LE_DFT_TX_POWER_LEVEL_DBM_EFF
|
||||
int
|
||||
default -15 if BT_LE_DFT_TX_POWER_LEVEL_N15
|
||||
default -12 if BT_LE_DFT_TX_POWER_LEVEL_N12
|
||||
default -9 if BT_LE_DFT_TX_POWER_LEVEL_N9
|
||||
default -6 if BT_LE_DFT_TX_POWER_LEVEL_N6
|
||||
default -3 if BT_LE_DFT_TX_POWER_LEVEL_N3
|
||||
default 0 if BT_LE_DFT_TX_POWER_LEVEL_N0
|
||||
default 3 if BT_LE_DFT_TX_POWER_LEVEL_P3
|
||||
default 6 if BT_LE_DFT_TX_POWER_LEVEL_P6
|
||||
default 9 if BT_LE_DFT_TX_POWER_LEVEL_P9
|
||||
default 12 if BT_LE_DFT_TX_POWER_LEVEL_P12
|
||||
default 15 if BT_LE_DFT_TX_POWER_LEVEL_P15
|
||||
default 18 if BT_LE_DFT_TX_POWER_LEVEL_P18
|
||||
default 20 if BT_LE_DFT_TX_POWER_LEVEL_P20
|
||||
default 0
|
||||
|
||||
config BT_LE_CTRL_CHECK_CONNECT_IND_ACCESS_ADDRESS
|
||||
bool "Enable enhanced Access Address check in CONNECT_IND"
|
||||
default n
|
||||
help
|
||||
Enabling this option will add stricter verification of the Access Address in the CONNECT_IND PDU.
|
||||
This improves security by ensuring that only connection requests with valid Access Addresses are accepted.
|
||||
If disabled, only basic checks are applied, improving compatibility.
|
||||
|
||||
config BT_CTRL_RUN_IN_FLASH_ONLY
|
||||
bool "Reduce BLE IRAM usage (READ DOCS FIRST) (EXPERIMENTAL)"
|
||||
default n
|
||||
help
|
||||
Move most IRAM into flash. This will increase the usage of flash and reduce ble performance.
|
||||
Because the code is moved to the flash, the execution speed of the code is reduced.
|
||||
To have a small impact on performance, you need to enable flash suspend (SPI_FLASH_AUTO_SUSPEND).
|
||||
|
Reference in New Issue