adc: no longer support adc2 oneshot mode on esp32c3

Due to HW limitation, we don't support this anymore. On c3, ADC2 under oneshot mode is not stable.

However, you can enable CONFIG_ADC_ONESHOT_FORCE_USE_ADC2_ON_C3 to force use
ADC2.

Refer to errata to know more details:
https://www.espressif.com/sites/default/files/documentation/esp32-c3_errata_en.pdf
This commit is contained in:
Armando
2022-12-16 12:53:04 +08:00
committed by BOT
parent 9b4986dd2c
commit 984ee9dd38
4 changed files with 19 additions and 9 deletions

View File

@@ -60,6 +60,7 @@ ADC Limitations
- A specific ADC module can only work under one operating mode at any one time, either Continuous Read Mode or Single Read Mode.
- For continuous (DMA) read mode, the ADC sampling frequency (the ``sample_freq_hz`` member of :cpp:type:`adc_digi_config_t`) should be within ``SOC_ADC_SAMPLE_FREQ_THRES_LOW`` and ``SOC_ADC_SAMPLE_FREQ_THRES_HIGH``
- ADC2 continuous (DMA) mode is no longer supported, due to hardware limitation. The results are not stable. This issue can be found in `ESP32C3 Errata <https://www.espressif.com/sites/default/files/documentation/esp32-c3_errata_en.pdf>`. For compatibility, you can enable :ref:`CONFIG_ADC_CONTINUOUS_FORCE_USE_ADC2_ON_C3_S3` to force use ADC2.
- ADC2 oneshot mode is no longer supported, due to hardware limitation. The results are not stable. This issue can be found in `ESP32C3 Errata <https://www.espressif.com/sites/default/files/documentation/esp32-c3_errata_en.pdf>`. For compatibility, you can enable :ref:`CONFIG_ADC_ONESHOT_FORCE_USE_ADC2_ON_C3` to force use ADC2.