adc: no longer support adc2 continuous mode on esp32c3 and esp32s3
Due to HW limitation, we don't support this anymore. On s3 and c3, ADC2 under continuous mode is not stable. However, you can enable CONFIG_ADC_CONTINUOUS_FORCE_USE_ADC2_ON_C3_S3 to force use ADC2. Refer to errata to know more details: https://www.espressif.com/sites/default/files/documentation/esp32-s3_errata_en.pdf https://www.espressif.com/sites/default/files/documentation/esp32-c3_errata_en.pdf
This commit is contained in:
@@ -55,5 +55,15 @@ menu "ADC and ADC Calibration"
|
||||
|
||||
Disable this option so as to measure the output of DAC by internal ADC, for test usage.
|
||||
|
||||
config ADC_CONTINUOUS_FORCE_USE_ADC2_ON_C3_S3
|
||||
depends on IDF_TARGET_ESP32C3 || IDF_TARGET_ESP32S3
|
||||
bool "Force use ADC2 continumous mode on ESP32S3 or ESP32C3"
|
||||
default n
|
||||
help
|
||||
On ESP32C3 and ESP32S3, ADC2 Digital Controller is not stable. Therefore,
|
||||
ADC2 continuous mode is not suggested on ESP32S3 and ESP32C3
|
||||
|
||||
If you stick to this, you can enable this option to force use ADC2 under above conditions.
|
||||
For more details, you can search for errata on espressif website.
|
||||
|
||||
endmenu
|
||||
|
@@ -530,16 +530,27 @@ esp_err_t adc_continuous_config(adc_continuous_handle_t handle, const adc_contin
|
||||
|
||||
//Pattern related check
|
||||
ESP_RETURN_ON_FALSE(config->pattern_num <= SOC_ADC_PATT_LEN_MAX, ESP_ERR_INVALID_ARG, ADC_TAG, "Max pattern num is %d", SOC_ADC_PATT_LEN_MAX);
|
||||
#if CONFIG_IDF_TARGET_ESP32
|
||||
for (int i = 0; i < config->pattern_num; i++) {
|
||||
ESP_RETURN_ON_FALSE((config->adc_pattern[i].bit_width >= SOC_ADC_DIGI_MIN_BITWIDTH && config->adc_pattern->bit_width <= SOC_ADC_DIGI_MAX_BITWIDTH), ESP_ERR_INVALID_ARG, ADC_TAG, "ADC bitwidth not supported");
|
||||
ESP_RETURN_ON_FALSE(config->adc_pattern[i].unit == 0, ESP_ERR_INVALID_ARG, ADC_TAG, "Only support using ADC1 DMA mode");
|
||||
}
|
||||
#else
|
||||
|
||||
for (int i = 0; i < config->pattern_num; i++) {
|
||||
ESP_RETURN_ON_FALSE((config->adc_pattern[i].bit_width == SOC_ADC_DIGI_MAX_BITWIDTH), ESP_ERR_INVALID_ARG, ADC_TAG, "ADC bitwidth not supported");
|
||||
#if CONFIG_IDF_TARGET_ESP32C3 || CONFIG_IDF_TARGET_ESP32S3
|
||||
//we add this error log to hint users what happened
|
||||
if (SOC_ADC_DIG_SUPPORTED_UNIT(config->adc_pattern[i].unit) == 0) {
|
||||
ESP_LOGE(ADC_TAG, "ADC2 continuous mode is no longer supported, please use ADC1. Search for errata on espressif website for more details. You can enable CONFIG_ADC_CONTINUOUS_FORCE_USE_ADC2_ON_C3_S3 to force use ADC2");
|
||||
}
|
||||
#endif //CONFIG_IDF_TARGET_ESP32C3 || CONFIG_IDF_TARGET_ESP32S3
|
||||
|
||||
#if !CONFIG_ADC_CONTINUOUS_FORCE_USE_ADC2_ON_C3_S3
|
||||
/**
|
||||
* On all continuous mode supported chips, we will always check the unit to see if it's a continuous mode supported unit.
|
||||
* However, on ESP32C3 and ESP32S3, we will jump this check, if `CONFIG_ADC_CONTINUOUS_FORCE_USE_ADC2_ON_C3_S3` is enabled.
|
||||
*/
|
||||
ESP_RETURN_ON_FALSE(SOC_ADC_DIG_SUPPORTED_UNIT(config->adc_pattern[i].unit), ESP_ERR_INVALID_ARG, ADC_TAG, "Only support using ADC1 DMA mode");
|
||||
#endif //#if !CONFIG_ADC_CONTINUOUS_FORCE_USE_ADC2_ON_C3_S3
|
||||
}
|
||||
#endif
|
||||
|
||||
ESP_RETURN_ON_FALSE(config->sample_freq_hz <= SOC_ADC_SAMPLE_FREQ_THRES_HIGH && config->sample_freq_hz >= SOC_ADC_SAMPLE_FREQ_THRES_LOW, ESP_ERR_INVALID_ARG, ADC_TAG, "ADC sampling frequency out of range");
|
||||
|
||||