fix(adc): rename ADC_ATTEN_DB_11 to ADC_ATTEN_DB_12
By design, it's 12 dB. There're errors among chips, so the actual attenuation will be 11dB more or less
This commit is contained in:
@@ -190,7 +190,7 @@ esp_err_t adc_cali_create_scheme_line_fitting(const adc_cali_line_fitting_config
|
||||
chars->atten = config->atten;
|
||||
chars->bitwidth = (config->bitwidth == ADC_BITWIDTH_DEFAULT) ? ADC_BITWIDTH_12 : config->bitwidth;
|
||||
//Initialize fields for lookup table if necessary
|
||||
if (LUT_ENABLED && config->atten == ADC_ATTEN_DB_11) {
|
||||
if (LUT_ENABLED && config->atten == ADC_ATTEN_DB_12) {
|
||||
chars->low_curve = (config->unit_id == ADC_UNIT_1) ? lut_adc1_low : lut_adc2_low;
|
||||
chars->high_curve = (config->unit_id == ADC_UNIT_1) ? lut_adc1_high : lut_adc2_high;
|
||||
} else {
|
||||
@@ -251,8 +251,8 @@ static esp_err_t cali_raw_to_voltage(void *arg, int raw, int *voltage)
|
||||
raw = ADC_12_BIT_RES - 1; //Set to 12bit res max
|
||||
}
|
||||
|
||||
if (LUT_ENABLED && (ctx->atten == ADC_ATTEN_DB_11) && (raw >= LUT_LOW_THRESH)) { //Check if in non-linear region
|
||||
//Use lookup table to get voltage in non linear portion of ADC_ATTEN_DB_11
|
||||
if (LUT_ENABLED && (ctx->atten == ADC_ATTEN_DB_12) && (raw >= LUT_LOW_THRESH)) { //Check if in non-linear region
|
||||
//Use lookup table to get voltage in non linear portion of ADC_ATTEN_DB_12
|
||||
uint32_t lut_voltage = calculate_voltage_lut(raw, ctx->vref, ctx->low_curve, ctx->high_curve);
|
||||
if (raw <= LUT_HIGH_THRESH) { //If ADC is transitioning from linear region to non-linear region
|
||||