menu "Brownout Detector"
 | 
						|
 | 
						|
    config ESP_BROWNOUT_DET
 | 
						|
        bool "Hardware brownout detect & reset"
 | 
						|
        depends on !IDF_ENV_FPGA
 | 
						|
        default y
 | 
						|
        help
 | 
						|
            The ESP32-S3 has a built-in brownout detector which can detect if the voltage is lower than
 | 
						|
            a specific value. If this happens, it will reset the chip in order to prevent unintended
 | 
						|
            behaviour.
 | 
						|
 | 
						|
    choice ESP_BROWNOUT_DET_LVL_SEL
 | 
						|
        prompt "Brownout voltage level"
 | 
						|
        depends on ESP_BROWNOUT_DET
 | 
						|
        default ESP_BROWNOUT_DET_LVL_SEL_7
 | 
						|
        help
 | 
						|
            The brownout detector will reset the chip when the supply voltage is approximately
 | 
						|
            below this level. Note that there may be some variation of brownout voltage level
 | 
						|
            between each ESP3-S3 chip.
 | 
						|
 | 
						|
            #The voltage levels here are estimates, more work needs to be done to figure out the exact voltages
 | 
						|
            #of the brownout threshold levels.
 | 
						|
        config ESP_BROWNOUT_DET_LVL_SEL_7
 | 
						|
            bool "2.44V"
 | 
						|
        config ESP_BROWNOUT_DET_LVL_SEL_6
 | 
						|
            bool "2.56V"
 | 
						|
        config ESP_BROWNOUT_DET_LVL_SEL_5
 | 
						|
            bool "2.67V"
 | 
						|
        config ESP_BROWNOUT_DET_LVL_SEL_4
 | 
						|
            bool "2.84V"
 | 
						|
        config ESP_BROWNOUT_DET_LVL_SEL_3
 | 
						|
            bool "2.98V"
 | 
						|
        config ESP_BROWNOUT_DET_LVL_SEL_2
 | 
						|
            bool "3.19V"
 | 
						|
        config ESP_BROWNOUT_DET_LVL_SEL_1
 | 
						|
            bool "3.30V"
 | 
						|
    endchoice
 | 
						|
 | 
						|
    config ESP_BROWNOUT_DET_LVL
 | 
						|
        int
 | 
						|
        default 1 if ESP_BROWNOUT_DET_LVL_SEL_1
 | 
						|
        default 2 if ESP_BROWNOUT_DET_LVL_SEL_2
 | 
						|
        default 3 if ESP_BROWNOUT_DET_LVL_SEL_3
 | 
						|
        default 4 if ESP_BROWNOUT_DET_LVL_SEL_4
 | 
						|
        default 5 if ESP_BROWNOUT_DET_LVL_SEL_5
 | 
						|
        default 6 if ESP_BROWNOUT_DET_LVL_SEL_6
 | 
						|
        default 7 if ESP_BROWNOUT_DET_LVL_SEL_7
 | 
						|
 | 
						|
endmenu
 |