mirror of
				https://github.com/espressif/esp-idf.git
				synced 2025-10-30 20:51:41 +00:00 
			
		
		
		
	
		
			
				
	
	
		
			149 lines
		
	
	
		
			5.4 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
			
		
		
	
	
			149 lines
		
	
	
		
			5.4 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
| // Copyright 2020 Espressif Systems (Shanghai) PTE LTD
 | |
| //
 | |
| // Licensed under the Apache License, Version 2.0 (the "License");
 | |
| // you may not use this file except in compliance with the License.
 | |
| // You may obtain a copy of the License at
 | |
| //
 | |
| //     http://www.apache.org/licenses/LICENSE-2.0
 | |
| //
 | |
| // Unless required by applicable law or agreed to in writing, software
 | |
| // distributed under the License is distributed on an "AS IS" BASIS,
 | |
| // WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
 | |
| // See the License for the specific language governing permissions and
 | |
| // limitations under the License.
 | |
| 
 | |
| #include <sys/param.h>
 | |
| #include <assert.h>
 | |
| #include "soc/soc_caps.h"
 | |
| #include "hal/systimer_hal.h"
 | |
| #include "hal/systimer_ll.h"
 | |
| #include "hal/systimer_types.h"
 | |
| #include "soc/rtc.h"
 | |
| 
 | |
| #define SYSTIMER_TICKS_PER_US (80) // Number of timer ticks per microsecond
 | |
| 
 | |
| uint64_t systimer_hal_get_counter_value(systimer_counter_id_t counter_id)
 | |
| {
 | |
|     uint32_t lo, lo_start, hi;
 | |
|     /* Set the "update" bit and wait for acknowledgment */
 | |
|     systimer_ll_counter_snapshot();
 | |
|     while (!systimer_ll_is_counter_value_valid());
 | |
|     /* Read LO, HI, then LO again, check that LO returns the same value.
 | |
|      * This accounts for the case when an interrupt may happen between reading
 | |
|      * HI and LO values, and this function may get called from the ISR.
 | |
|      * In this case, the repeated read will return consistent values.
 | |
|      */
 | |
|     lo_start = systimer_ll_get_counter_value_low();
 | |
|     do {
 | |
|         lo = lo_start;
 | |
|         hi = systimer_ll_get_counter_value_high();
 | |
|         lo_start = systimer_ll_get_counter_value_low();
 | |
|     } while (lo_start != lo);
 | |
| 
 | |
|     systimer_counter_value_t result = {
 | |
|         .lo = lo,
 | |
|         .hi = hi
 | |
|     };
 | |
| 
 | |
|     return result.val;
 | |
| }
 | |
| 
 | |
| uint64_t systimer_hal_get_time(systimer_counter_id_t counter_id)
 | |
| {
 | |
|     return systimer_hal_get_counter_value(counter_id) / SYSTIMER_TICKS_PER_US;
 | |
| }
 | |
| 
 | |
| void systimer_hal_set_alarm_target(systimer_alarm_id_t alarm_id, uint64_t timestamp)
 | |
| {
 | |
|     int64_t offset = SYSTIMER_TICKS_PER_US * 2;
 | |
|     uint64_t now_time = systimer_hal_get_counter_value(SYSTIMER_COUNTER_0);
 | |
|     systimer_counter_value_t alarm = { .val = MAX(timestamp * SYSTIMER_TICKS_PER_US, now_time + offset) };
 | |
|     do {
 | |
|         systimer_ll_disable_alarm(alarm_id);
 | |
|         systimer_ll_set_alarm_value(alarm_id, alarm.val);
 | |
|         systimer_ll_enable_alarm(alarm_id);
 | |
|         now_time = systimer_hal_get_counter_value(SYSTIMER_COUNTER_0);
 | |
|         int64_t delta = (int64_t)alarm.val - (int64_t)now_time;
 | |
|         if (delta <= 0 && !systimer_ll_is_alarm_int_fired(alarm_id)) {
 | |
|             // new alarm is less than the counter and the interrupt flag is not set
 | |
|             offset += -1 * delta + SYSTIMER_TICKS_PER_US * 2;
 | |
|             alarm.val = now_time + offset;
 | |
|         } else {
 | |
|             // finish if either (alarm > counter) or the interrupt flag is already set.
 | |
|             break;
 | |
|         }
 | |
|     } while (1);
 | |
| }
 | |
| 
 | |
| uint64_t systimer_hal_get_alarm_value(systimer_alarm_id_t alarm_id)
 | |
| {
 | |
|     return systimer_ll_get_alarm_value(alarm_id);
 | |
| }
 | |
| 
 | |
| void systimer_hal_enable_alarm_int(systimer_alarm_id_t alarm_id)
 | |
| {
 | |
|     systimer_ll_enable_alarm_int(alarm_id);
 | |
| }
 | |
| 
 | |
| void systimer_hal_on_apb_freq_update(uint32_t apb_ticks_per_us)
 | |
| {
 | |
|     /* If this function was called when switching APB clock to PLL, don't need
 | |
|      * do anything: the SYSTIMER_TIMER_PLL_STEP is already correct.
 | |
|      * If this was called when switching APB clock to XTAL, need to adjust
 | |
|      * XTAL_STEP value accordingly.
 | |
|      */
 | |
|     if (apb_ticks_per_us != SYSTIMER_TICKS_PER_US) {
 | |
|         assert((SYSTIMER_TICKS_PER_US % apb_ticks_per_us) == 0 && "TICK_PER_US should be divisible by APB frequency (in MHz)");
 | |
|         systimer_ll_set_step_for_xtal(SYSTIMER_TICKS_PER_US / apb_ticks_per_us);
 | |
|     }
 | |
| }
 | |
| 
 | |
| void systimer_hal_counter_value_advance(systimer_counter_id_t counter_id, int64_t time_us)
 | |
| {
 | |
|     systimer_counter_value_t new_count = { .val = systimer_hal_get_counter_value(counter_id) + time_us * SYSTIMER_TICKS_PER_US };
 | |
|     systimer_ll_load_counter_value(new_count.val);
 | |
|     systimer_ll_apply_counter_value();
 | |
| }
 | |
| 
 | |
| void systimer_hal_enable_counter(systimer_counter_id_t counter_id)
 | |
| {
 | |
|     (void)counter_id;
 | |
| }
 | |
| 
 | |
| void systimer_hal_init(void)
 | |
| {
 | |
|     assert(rtc_clk_xtal_freq_get() == 40 && "update the step for xtal to support other XTAL:APB frequency ratios");
 | |
|     systimer_ll_enable_clock();
 | |
|     /* Configure the counter:
 | |
|      * - increment by 1 when running from PLL (80 ticks per microsecond),
 | |
|      * - increment by 2 when running from XTAL (40 ticks per microsecond).
 | |
|      * Note that if the APB frequency is derived from XTAL with divider != 1,
 | |
|      * XTAL_STEP needs to be adjusted accordingly. For example, if
 | |
|      * the APB frequency is XTAL/4 = 10 MHz, then XTAL_STEP should be set to 8.
 | |
|      * This is handled in systimer_hal_on_apb_freq_update function.
 | |
|      */
 | |
|     systimer_ll_set_step_for_pll(1);
 | |
|     systimer_ll_set_step_for_xtal(2);
 | |
| }
 | |
| 
 | |
| void systimer_hal_select_alarm_mode(systimer_alarm_id_t alarm_id, systimer_alarm_mode_t mode)
 | |
| {
 | |
|     switch (mode) {
 | |
|     case SYSTIMER_ALARM_MODE_ONESHOT:
 | |
|         systimer_ll_enable_alarm_oneshot(alarm_id);
 | |
|         break;
 | |
|     case SYSTIMER_ALARM_MODE_PERIOD:
 | |
|         systimer_ll_enable_alarm_period(alarm_id);
 | |
|         break;
 | |
|     default:
 | |
|         break;
 | |
|     }
 | |
| }
 | |
| 
 | |
| void systimer_hal_connect_alarm_counter(systimer_alarm_id_t alarm_id, systimer_counter_id_t counter_id)
 | |
| {
 | |
|     // esp32s2 only has one counter, so there's no need to connect alarm unit to counter
 | |
|     (void)alarm_id;
 | |
|     (void)counter_id;
 | |
| }
 | 
