mirror of
				https://github.com/espressif/esp-idf.git
				synced 2025-11-04 06:11:06 +00:00 
			
		
		
		
	
		
			
				
	
	
		
			149 lines
		
	
	
		
			5.4 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
			
		
		
	
	
			149 lines
		
	
	
		
			5.4 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
// Copyright 2020 Espressif Systems (Shanghai) PTE LTD
 | 
						|
//
 | 
						|
// Licensed under the Apache License, Version 2.0 (the "License");
 | 
						|
// you may not use this file except in compliance with the License.
 | 
						|
// You may obtain a copy of the License at
 | 
						|
//
 | 
						|
//     http://www.apache.org/licenses/LICENSE-2.0
 | 
						|
//
 | 
						|
// Unless required by applicable law or agreed to in writing, software
 | 
						|
// distributed under the License is distributed on an "AS IS" BASIS,
 | 
						|
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
 | 
						|
// See the License for the specific language governing permissions and
 | 
						|
// limitations under the License.
 | 
						|
 | 
						|
#include <sys/param.h>
 | 
						|
#include <assert.h>
 | 
						|
#include "soc/soc_caps.h"
 | 
						|
#include "hal/systimer_hal.h"
 | 
						|
#include "hal/systimer_ll.h"
 | 
						|
#include "hal/systimer_types.h"
 | 
						|
#include "soc/rtc.h"
 | 
						|
 | 
						|
#define SYSTIMER_TICKS_PER_US (80) // Number of timer ticks per microsecond
 | 
						|
 | 
						|
uint64_t systimer_hal_get_counter_value(systimer_counter_id_t counter_id)
 | 
						|
{
 | 
						|
    uint32_t lo, lo_start, hi;
 | 
						|
    /* Set the "update" bit and wait for acknowledgment */
 | 
						|
    systimer_ll_counter_snapshot();
 | 
						|
    while (!systimer_ll_is_counter_value_valid());
 | 
						|
    /* Read LO, HI, then LO again, check that LO returns the same value.
 | 
						|
     * This accounts for the case when an interrupt may happen between reading
 | 
						|
     * HI and LO values, and this function may get called from the ISR.
 | 
						|
     * In this case, the repeated read will return consistent values.
 | 
						|
     */
 | 
						|
    lo_start = systimer_ll_get_counter_value_low();
 | 
						|
    do {
 | 
						|
        lo = lo_start;
 | 
						|
        hi = systimer_ll_get_counter_value_high();
 | 
						|
        lo_start = systimer_ll_get_counter_value_low();
 | 
						|
    } while (lo_start != lo);
 | 
						|
 | 
						|
    systimer_counter_value_t result = {
 | 
						|
        .lo = lo,
 | 
						|
        .hi = hi
 | 
						|
    };
 | 
						|
 | 
						|
    return result.val;
 | 
						|
}
 | 
						|
 | 
						|
uint64_t systimer_hal_get_time(systimer_counter_id_t counter_id)
 | 
						|
{
 | 
						|
    return systimer_hal_get_counter_value(counter_id) / SYSTIMER_TICKS_PER_US;
 | 
						|
}
 | 
						|
 | 
						|
void systimer_hal_set_alarm_target(systimer_alarm_id_t alarm_id, uint64_t timestamp)
 | 
						|
{
 | 
						|
    int64_t offset = SYSTIMER_TICKS_PER_US * 2;
 | 
						|
    uint64_t now_time = systimer_hal_get_counter_value(SYSTIMER_COUNTER_0);
 | 
						|
    systimer_counter_value_t alarm = { .val = MAX(timestamp * SYSTIMER_TICKS_PER_US, now_time + offset) };
 | 
						|
    do {
 | 
						|
        systimer_ll_disable_alarm(alarm_id);
 | 
						|
        systimer_ll_set_alarm_value(alarm_id, alarm.val);
 | 
						|
        systimer_ll_enable_alarm(alarm_id);
 | 
						|
        now_time = systimer_hal_get_counter_value(SYSTIMER_COUNTER_0);
 | 
						|
        int64_t delta = (int64_t)alarm.val - (int64_t)now_time;
 | 
						|
        if (delta <= 0 && !systimer_ll_is_alarm_int_fired(alarm_id)) {
 | 
						|
            // new alarm is less than the counter and the interrupt flag is not set
 | 
						|
            offset += -1 * delta + SYSTIMER_TICKS_PER_US * 2;
 | 
						|
            alarm.val = now_time + offset;
 | 
						|
        } else {
 | 
						|
            // finish if either (alarm > counter) or the interrupt flag is already set.
 | 
						|
            break;
 | 
						|
        }
 | 
						|
    } while (1);
 | 
						|
}
 | 
						|
 | 
						|
uint64_t systimer_hal_get_alarm_value(systimer_alarm_id_t alarm_id)
 | 
						|
{
 | 
						|
    return systimer_ll_get_alarm_value(alarm_id);
 | 
						|
}
 | 
						|
 | 
						|
void systimer_hal_enable_alarm_int(systimer_alarm_id_t alarm_id)
 | 
						|
{
 | 
						|
    systimer_ll_enable_alarm_int(alarm_id);
 | 
						|
}
 | 
						|
 | 
						|
void systimer_hal_on_apb_freq_update(uint32_t apb_ticks_per_us)
 | 
						|
{
 | 
						|
    /* If this function was called when switching APB clock to PLL, don't need
 | 
						|
     * do anything: the SYSTIMER_TIMER_PLL_STEP is already correct.
 | 
						|
     * If this was called when switching APB clock to XTAL, need to adjust
 | 
						|
     * XTAL_STEP value accordingly.
 | 
						|
     */
 | 
						|
    if (apb_ticks_per_us != SYSTIMER_TICKS_PER_US) {
 | 
						|
        assert((SYSTIMER_TICKS_PER_US % apb_ticks_per_us) == 0 && "TICK_PER_US should be divisible by APB frequency (in MHz)");
 | 
						|
        systimer_ll_set_step_for_xtal(SYSTIMER_TICKS_PER_US / apb_ticks_per_us);
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
void systimer_hal_counter_value_advance(systimer_counter_id_t counter_id, int64_t time_us)
 | 
						|
{
 | 
						|
    systimer_counter_value_t new_count = { .val = systimer_hal_get_counter_value(counter_id) + time_us * SYSTIMER_TICKS_PER_US };
 | 
						|
    systimer_ll_load_counter_value(new_count.val);
 | 
						|
    systimer_ll_apply_counter_value();
 | 
						|
}
 | 
						|
 | 
						|
void systimer_hal_enable_counter(systimer_counter_id_t counter_id)
 | 
						|
{
 | 
						|
    (void)counter_id;
 | 
						|
}
 | 
						|
 | 
						|
void systimer_hal_init(void)
 | 
						|
{
 | 
						|
    assert(rtc_clk_xtal_freq_get() == 40 && "update the step for xtal to support other XTAL:APB frequency ratios");
 | 
						|
    systimer_ll_enable_clock();
 | 
						|
    /* Configure the counter:
 | 
						|
     * - increment by 1 when running from PLL (80 ticks per microsecond),
 | 
						|
     * - increment by 2 when running from XTAL (40 ticks per microsecond).
 | 
						|
     * Note that if the APB frequency is derived from XTAL with divider != 1,
 | 
						|
     * XTAL_STEP needs to be adjusted accordingly. For example, if
 | 
						|
     * the APB frequency is XTAL/4 = 10 MHz, then XTAL_STEP should be set to 8.
 | 
						|
     * This is handled in systimer_hal_on_apb_freq_update function.
 | 
						|
     */
 | 
						|
    systimer_ll_set_step_for_pll(1);
 | 
						|
    systimer_ll_set_step_for_xtal(2);
 | 
						|
}
 | 
						|
 | 
						|
void systimer_hal_select_alarm_mode(systimer_alarm_id_t alarm_id, systimer_alarm_mode_t mode)
 | 
						|
{
 | 
						|
    switch (mode) {
 | 
						|
    case SYSTIMER_ALARM_MODE_ONESHOT:
 | 
						|
        systimer_ll_enable_alarm_oneshot(alarm_id);
 | 
						|
        break;
 | 
						|
    case SYSTIMER_ALARM_MODE_PERIOD:
 | 
						|
        systimer_ll_enable_alarm_period(alarm_id);
 | 
						|
        break;
 | 
						|
    default:
 | 
						|
        break;
 | 
						|
    }
 | 
						|
}
 | 
						|
 | 
						|
void systimer_hal_connect_alarm_counter(systimer_alarm_id_t alarm_id, systimer_counter_id_t counter_id)
 | 
						|
{
 | 
						|
    // esp32s2 only has one counter, so there's no need to connect alarm unit to counter
 | 
						|
    (void)alarm_id;
 | 
						|
    (void)counter_id;
 | 
						|
}
 |